ID 4200
115V
|
ID 4300
230V
|
ID 4400
230V
|
ID 4500
REMOTE CONDENSED
|
|
|
|
Refrigeration System
|
|
R-502
|
R-404
|
R-404A
|
R-404A
|
|
|
Compressor H.P.
|
|
(1) 3/4 hp
|
(1) 3/4 hp
|
(1) 1.2 hp
|
Requires separate Condensing unit
P/N 1460 2 1/2hp compressor
|
|
|
Electrical Requirements
|
115v/20amp
Min. Circuit
|
208-230v/20amp
Min. Circuit
|
208-230v/20amp
Min. Circuit
|
Dispenser
115v/15amp
Remote Compressor
208-230v/30amp 60Hz 1ph
|
|
|
Water and Drain
|
|
Not Applicable
|
Not Applicable
|
Not Applicable
|
Not Applicable
|
|
Capacity:
Cylinder
Hopper
Total
|
5.0 Quarts
9.0 Quarts
12.5 Quarts
|
5.0 qts x 2
9.0 qts x 2
14.0 qts x 2
|
5.0 qts x 2
9.0 qts x 2
14.0 qts x 2
|
5.0 qts x 2
9.0 qts x 2
14.0 qts x 2
|
|
Physical Properties:
Height
Width
Depth
Weight
|
31"
16.7"
26.5"
195 lbs
|
31"
16.7"
26.5"
195 lbs
|
31"
16.7"
26.5"
195 lbs
|
31"
16.7"
26.5"
140 lbs without condensing unit
|
|
|
Ventilation
|
Add six inches for
proper ventilation.
|
Add six inches for
proper ventilation.
|
Add six inches for
proper ventilation.
|
Add six inches for
proper ventilation.
|
|
|
Standard Freeze Down
|
40 min with product
@ 75 degrees F
|
40 min with product
@ 75 degrees F
|
40 min with product
@ 75 degrees F
|
22 min with product
@ 75 degrees F
|
|
|
Peak Demand
|
|
10 servings* / min x 2
|
10 servings* / min x 2
|
10 servings* / min x 2
|
13 servings* / min x 2
|
|
|
Standard Draw Rate
|
|
1 serving* every min x 2
|
1 serving* every min x 2
|
1 serving* every min x 2
|
3 servings* / min x 2
|
|
|
Per Cylinder
|
|
47 servings* / hr x 2
|
47 servings* / hr x 2
|
47 servings* / hr x 2
|
180 servings* / hr x 2
|
|
|
Per Dispenser
|
|
5.1 gallons / hr x 2
|
5.1 gallons / hr x 2
|
5.1 gallons / hr x 2
|
19.0 gallons / hr x 2
|
|
| |
*14 Oz. servings
|
| |
Due to ongoing development, all specifications are subject to change without notice.
Operator practices and environmental factors may affect performance.
|
| |
| |
|
Options:
|
(1) Counter
|
(2) Under Counter
|
(3) Remote Auto Feed
|
|
| |
| |
NOTE: Warranty coverage may vary depending on model number and program type.